IPG Photonics offers CLPN and CLPNT Cr:ZnSe/S pulsed nanosecond Mid-IR lasers. Customer can select a fixed frequency or tunable model in 2.4 - 3.0 micron range. These lasers provides pulse energies up to 3 mJ, pulse duration 0.7 - 15 ns and pulse repetition rate up to 2 kHz. The lasers are pumped by IPG Photonics’ efficient and reliable thulium fiber laser. CLPN and CLPNT pulsed Mid-IR lasers are used for materials processing, environmental monitoring and medical applications.
Selectable Wavelength 2.4-3.0 mm | Excellent Beam Quality |
Pulse Energy > 3 mJ | Pulse Width 0.7-15 ns |
Repetition Rate 0.1-2 kHz | Compact and Low Cost |
CLPN | CLPNT | |
Mode of Operation | Pulsed | |
Central Wavelength | fixed, customer selected in 2.4-3.0 μm range | tunable, user-selected in 2.4-3.0 μm range |
Pulse Energy, mJ | 1 - 3 | |
Pulse Duration, ns | 0.7 -15 | |
Maximum Average Power, W | 3 |
|
Repetition Rate, kHz | 0.1-2.0 | |
Beam Mode Quality, M2 |
<5 | |
Polarization | Random or Linear | Linear, Horizontal, >100 :1 |
Beam Waist Diameter, mm |
<4.5 | |
Warm Up Time. min | <5 from standby, 15 from cold start |
Pump Laser |
IPG Photonics Thulium CW Fiber Laser |
||
Pump Laser Dimensions (W × D × H), mm | 448 × 403 × 132 | ||
Pump Laser Cooling | Air | ||
Optical Head Dimensions (W × D × H), mm | 270 × 300 × 110 (air cooled) or 260 × 206 × 72 (water cooled) | ||
Optical Head Cooling | Air | ||
Supply Voltage, VAC | 110-240 | ||
Power Consumption*, W | 100-800 |
* Electrical power consumption depends on the output energy of the system
Medical Applications | Industrial Process Control |
Environmental Monitoring | Materials Processing |