TLM and TLR Thulium Fiber Laser Systems have been developed specifically to meet the growing demands of the industrial, medical and R&D markets for high power, compact, efficient, wavelength-selectable CW sources of the spectral range of 1880 to 2050 nm. TLM and TLR fiber lasers are offered with single-mode or multi-mode beam quality optimal for the aopplication. First manufactured in 1999, these lasers have been field tested and deployed in a variety of R&D and medical applications. Now with higher powers and new options, the TLM and TLR Series provide the ideal solution for both laboratory, medical and industrial market segments.
Compact Size |
Wide Selection of Wavelengths |
High Wall-plug Efficiency | Advantage over CO2 & Ho:YAG |
Compact OEM Solution |
Low Cost |
Single-mode or Multi-mode Beam Quality Optimal for the Application |
TLM-100 | TLM-120 | TLM-200 | |
Central Wavelength Range*, nm | 1900-2050, typ. 1940 nm | 1900-2000, typ. 1940 | |
Linewidth FWHM, nm | <1 | ||
Mode of Operation | CW/Modulated | ||
Modulation Frequency, kHz | up to 1 | ||
Average Power, W | 100 | 120 | 200 |
Power Tunability, % | 10-100 | ||
Power Stability**, % | ±1 | ||
Optical Noise***, % RMS | 1 | ||
Single-mode Beam Quality, M2 | <1.1 | ||
Output Fiber Core Diameter, μm | 50, 100 and 200 (multi-mode) | ||
Beam Parameter Product, mm × mrad | <2, <5, <10 (multi mode) |
* Custom central wavelengths are available upon request
** Over 4 hours, T=const
*** 10 kHz - 20 MHz
TLM-100 | TLM-120 | TLM-200 | |
Module Dimensions (W × D × H), mm | TLM 200 W355 × 407 × 54 | ||
Cooling | Water-cooled | ||
Supply Voltage, VDC | 48 | ||
Power Consumption, W | <900 | <1200 | <1800 |
Compact Size |
Wide Selection of Wavelengths |
High Wall-plug Efficiency | Advantage over CO2 & Ho:YAG |
Compact OEM Solution |
Low Cost |
Single-mode or Multi-mode Beam Quality Optimal for the Application |
TLR-100 | TLR-120 | TLR-200 | TLR-500 | |
Central Wavelength Range*, nm | 1900-2050, 1943 typ. | 1900-2000, 1943 typ. | ||
Linewidth FWHM, nm | <1 | |||
Mode of Operation | CW/modulated | |||
Modulation Frequency, kHz | <1 | |||
Average Power, W | 100 | 120 | 200 | 500 |
Power Tunability, % | 10-200 | |||
Power Stability (Over 4 hours, T=const)**, % | ±1 | |||
Optical Noise***, % RMS | <2, typ.1 | |||
Polarization | Random | |||
Beam Mode Quality, M2 | <1.1 | N/A | ||
Output Fiber Core Diameter, μm | 50, 100 and 200 | |||
Beam Parameter Product, mm × mrad |
<3 @ 50 μm, 1.5 typ. |
* The default central emission wavelength is 1943 nm. Other wavelengths are available upon request. Maximum output power may be limited by wavelength selection.
** Over 4 hours, T=const
*** 10 kHz - 20 MHz
TLR-100 | TLR-120 | TLR-200 | TLR-500 | |
Console Dimensions, mm | TLR 100-200 W448 × 580× 133 |
TLR 500 W448 × 580 × 266 | ||
Cooling | Water | |||
Supply Voltage, VAC | 200-240, 50-60 Hz |
single phase 50-60 Hz, 110-240 | ||
Power Consumption, W | <1200 | <1400 | <1800 | <4500 |
Medical Treatment | Plastics Cutting and Welding |
Surgery | Non-metal Materials Processing |
Dermatology | Pollution Control / Remote Sensing |